Search
Products
Solutions
References
Acoustics
Functional demands
Contact
About Ecophon
Career
SITEMAP
Focus
Focus additional systems
Master
Combison
Gedina
Advantage
Access
Sombra
Hygiene
Super G
Wall Panel
Ecophon Lighting
Focus™ A
Focus™ B
Focus™ C
Focus™ Dg
Focus™ Ds
Focus™ E
Focus™ Ebx
Focus™ F
Focus™ Wing
Focus Edge™ 500
Ecophon Focus™ Flexiform
Focus™ S-Line
Focus™ L-Line
Ecophon Focus™ Quadro E
Focus™ Frieze
Master™ A
Master™ B
Master™ C
Master™ Ds
Master™ E
Master™ F
Master™ Solo S
Master™ Baffle
Combison™ Uno A
Combison™ Uno Ds
Combison™ Duo A
Combison™ Duo E
Combison™ Barrier
Gedina™ A
Gedina™ E
Advantage™ A
Advantage™ E
Access™ A
Access™ C
Access™ E
Access™ Frieze
Sombra™ A
Sombra™ Ds
Hygiene Advance™ A C4
Hygiene Advance™ A C3
Hygiene Advance™ Baffle C3
Hygiene Advance™ Protection C3
Hygiene Advance™ Wall C3
Hygiene Foodtec™ A C3
Hygiene Foodtec™ Baffle C3
Hygiene Foodtec™ Wall C3
Hygiene Protec™ A C3
Hygiene Protec™ A C1
Hygiene Labotec™ Ds C1
Hygiene Performance™ A C4
Hygiene Performance™ A C3
Hygiene Performance™ A C1
Hygiene Meditec™ A C1
Hygiene Meditec™ E C1
Hygiene Lavanda™ T5 C3
Hygiene Foodtec™ Protection C3
Super G™
Super G™ Plus
Super G™ Dp XL
Wall Panel™ A
Wall Panel™ C
Ecophon Illuminated Level Change
Light Coffer
Dot™
Square 43™
Line™
WingLight™
Room types
Ideas and solutions
Colours and surfaces
Integrated lighting
Download our brochures here!
Concrete Core Activation
Connect Grids
Local references Germany
Local references Italy
Local references Sweden
Local references Netherlands
Local references
For Architects
For Acousticians
For Clients
For Users
Sound in offices
Noise in Offices
Ecophon Acoustic Bulletin
Accessibility
Limpieza
Visual appearance
Environment
Our certifications
Influence of climate
Fire Safety
Mechanical properties
CE-marking
Ecophon partners
Request information
Contact
ECO magazine- subscription
Subscribe to EcoMagazine
Disclaimer
Cookies
Trademarks
Testimonials
Available jobs
Workplace facts
Development opportunities
Environment Health Safety
HR Contact
Access
Access™ A
Tell a friend
Print
E-tools
Cad Support
Specifications
Maintenance manual
System and product description
Installation
Acoustics
Technical info
System range
Size, mm
2000x577
2000x1177
Special Fixing
Thickness
27
27
M60
M60
System and product description
For corridors or areas with service installations in the ceiling void where frequent access is required. Ecophon Access A is arranged in rows, with a 23 mm space between individual panels and is mounted wall-to-wall, with or without margins in corridors. As an alternative Ecophon Access A can be installed in “rows” in a large area or room creating a visible grid pattern.
The system consists of Ecophon Access A panels and Connect Access grid systems, with an approximate weight of 4 kg/ m². The panel consists of a sound absorber and a channel profile frame. Two hangers are fitted to the frame. The absorber is manufactured from high density glass wool. The visible surface has an Akutex FT coating and the back of the absorber is covered with glass tissue. The channel profile frame and the grid are manufactured from galvanized steel.
M60
M60
Download installation guide
IG60
-Ecophon Access
(1.65 MB)
IG
-Access Universal profile
(409,98 kB)
IG
-Access profiles
(476.21 kB)
Quantity specification (excl. wastage)
Installation diagram (M60) for Ecophon Access A
Size, mm
2000x577
2000x1177
1 Ecophon Access A
-
-
A=Junction with wall (junction: A2_A21)
-
-
B=Junction with ceiling suspended from the soffit (junction: A2_A24)
-
-
C=Transition of ceiling with wall installation 1 (transition: A2_A23)
-
-
D=Transition of ceiling with wall installation 2 (transition: A2_A27)
-
-
E=Installation in double rows (transition: A2_A22)
-
-
Min. overall depth of system: 120 mm
-
-
Min. demounting depth: 80 mm
-
-
Acoustics
Acoustic:
αp Practical sound absorption coefficient
Frequency Hz
···Ecophon Wall Panel C/Texona 40 mm o.d.s.
---Ecophon Wall Panel C/Super G 40 mm o.d.s.
— Ecophon Wall Panel C/Akutex FT 40 mm o.d.s.
o.d.s = overall depth of system
Sound Absorption:
Test results according to EN ISO 354.
Classification according to EN ISO 11654, and the single value ratings for NRC and SAA according to ASTM C 423.
Sound Insulation:
Not applicable.
Sound Privacy:
AC=240 according to ASTM E 1376 and E 1110
product
Wall Panel C/Akutex FT
Wall Panel C/Super G
Wall Panel C/Texona
o.d.s mm
40
40
40
absorption class
A
A
A
Technical info
Accessibility:
The tiles are easily demountable. Minimum demounting depth according to installation diagrams.
Cleanability:
Daily dusting and vacuum cleaning. Weekly wet wiping.
Visual appearance:
White Frost, nearest NCS colour sample S 0500-N, 85% light reflectance (of which more than 99% is diffuse reflection). Retro reflection coefficient 63 mcd*m-2lx-1. Gloss < 1.
Influence of climate:
The tiles withstand a permanent ambient RH up to 95% at 30°C without sagging, warping or delaminating (ISO 4611).
Indoor Climate:
Certified by the Indoor Climate Labelling and recommended by the Swedish Asthma and Allergy Association.
Environmental influence:
Granted the Nordic Swan eco-label. Fully recyclable.
Fire safety:
The glass wool core of the tiles is tested and classified as non-combustible according to EN ISO 1182. See Technical properties, Fire safety.
Country
Class
Standard
Europe
EN 13501-1
A2-s1,d0
Mechanical properties:
For information regarding live load and requirements for load bearing capacity, see installation diagrams. Conditions: See Functional demands, Mechanical properties.
Installation:
Installed according to system range.
For Acousticians
"Acoustical evaluation of rooms requires several room acoustic descriptors. Reverberation time alone is not enough!" Erling Nilsson / Acoustics Specialist Ecophon
Copyright © 2002-2010 Ecophon Group. All rights reserved.