Search
Products
Solutions
References
Acoustics
Functional demands
Contact
About Ecophon
Career
SITEMAP
Focus
Focus additional systems
Master
Combison
Gedina
Advantage
Access
Sombra
Hygiene
Super G
Wall Panel
Ecophon Lighting
Focus™ A
Focus™ B
Focus™ C
Focus™ Dg
Focus™ Ds
Focus™ E
Focus™ Ebx
Focus™ F
Focus™ Wing
Focus Edge™ 500
Ecophon Focus™ Flexiform
Focus™ S-Line
Focus™ L-Line
Ecophon Focus™ Quadro E
Focus™ Frieze
Master™ A
Master™ B
Master™ C
Master™ Ds
Master™ E
Master™ F
Master™ Solo S
Master™ Baffle
Combison™ Uno A
Combison™ Uno Ds
Combison™ Duo A
Combison™ Duo E
Combison™ Barrier
Gedina™ A
Gedina™ E
Advantage™ A
Advantage™ E
Access™ A
Access™ C
Access™ E
Access™ Frieze
Sombra™ A
Sombra™ Ds
Hygiene Advance™ A C4
Hygiene Advance™ A C3
Hygiene Advance™ Baffle C3
Hygiene Advance™ Protection C3
Hygiene Advance™ Wall C3
Hygiene Foodtec™ A C3
Hygiene Foodtec™ Baffle C3
Hygiene Foodtec™ Wall C3
Hygiene Protec™ A C3
Hygiene Protec™ A C1
Hygiene Labotec™ Ds C1
Hygiene Performance™ A C4
Hygiene Performance™ A C3
Hygiene Performance™ A C1
Hygiene Meditec™ A C1
Hygiene Meditec™ E C1
Hygiene Lavanda™ T5 C3
Hygiene Foodtec™ Protection C3
Super G™
Super G™ Plus
Super G™ Dp XL
Wall Panel™ A
Wall Panel™ C
Ecophon Illuminated Level Change
Light Coffer
Dot™
Square 43™
Line™
WingLight™
Room types
Ideas and solutions
Colours and surfaces
Integrated lighting
Download our brochures here!
Concrete Core Activation
Connect Grids
Local references Germany
Local references Italy
Local references Sweden
Local references Netherlands
Local references
For Architects
For Acousticians
For Clients
For Users
Sound in offices
Noise in Offices
Ecophon Acoustic Bulletin
Accessibility
Limpieza
Visual appearance
Environment
Our certifications
Influence of climate
Fire Safety
Mechanical properties
CE-marking
Ecophon partners
Request information
Contact
ECO magazine- subscription
Subscribe to EcoMagazine
Disclaimer
Cookies
Trademarks
Testimonials
Available jobs
Workplace facts
Development opportunities
Environment Health Safety
HR Contact
Focus
Focus™ A
Tell a friend
Print
E-tools
Cad Support
Specifications
Maintenance manual
System and product description
Installation
Acoustics
Technical info
System range
Size, mm
XL
XL
XL
XL
600x600
1200x600
1200x1200
1600x600
1800x600
2000x600
2400x600
T15
•
•
•
T24
•
•
•
•
•
•
•
Thickness
20
20
20
20
20
20
20
M01
M01
M01
M16
M46
M16
M46
M16
M46
M16
M46
System and product description
For applications where a robust suspended ceiling system is required. Ecophon Focus A has an exposed grid system. Each tile is easily demountable.
The systems consist of Ecophon Focus A tiles and Ecophon Connect grid systems, with an approximate weight of 3 kg/m². The tiles are manufactured from high density glass wool. The visible surface has an Akutex FT coating and the back of the tile is covered with glass tissue. The edges are primed. The grid is manufactured from galvanized steel.
M01
M16
M46
M01
Download installation file
M01.wmf (458.99 kB)
Quantity specification (excl. wastage)
Installation diagram (M01) for Focus A
Size, mm
600x600
1200x600
1200x1200
1 Ecophon Focus A
2,8/m²
1,4/m²
0,7/m²
2 Connect T24 or T15 Main runner, installed at 1200 mm centres
0,9m/m²
0,9m/m²
0,9m/m²
3 Connect T24 or T15 Cross tee, L=1200 mm, installed at 600 mm centres
1,7m/m²
1,7m/m²
0,9m/m²
4 Connect T24 or T15 Cross tee, L=600 mm
0,9m/m²
-
-
5 Connect Adjustable hanger, installed at 1200 mm centres (max. distance from wall 600 mm)
0,7/m²
0,7/m²
0,7/m²
6 Connect Hanger clip
0,7/m²
0,7/m²
0,7/m²
7 For direct installation: Connect Direct bracket, installed at 1200 mm centres
0,7/m²
0,7/m²
0,7/m²
8 Connect Angle trim, fixed at 300 mm centres
as required
as required
as required
9 Connect Shadow-line trim, fixed at 300 mm centres
as required
as required
as required
Min. overall depth of system, with Adjustable hanger: 100 mm, with Direct bracket: 50 mm
-
-
-
Min. demounting depth: 120 mm (130 mm with 1200x1200)
-
-
-
M16
Quantity specification (excl. wastage)
Installation diagram (M16) for Focus A XL in corridors
Size, mm
1600x600
1800x600
2000x600
2400x600
1 Focus A
1,05/m²
0,95/m²
0,85/m²
0,7/m²
2 Connect T24 Corridor profile, installed at 600 mm centres
1,05/m²
0,95/m²
0,85/m²
0,7/m²
3 Connect Angle trim, fixed at 200 mm centres
as required
as required
as required
as required
4 Connect Shadow-line trim, fixed at 200 mm centres
as required
as required
as required
as required
Min. overall depth of system: 40 mm
-
-
-
-
Min. demounting depth: 65 mm
-
-
-
-
M46
Quantity specification (excl. wastage)
Installation diagram (M46) for Focus A XL
Size, mm
1600x600
1800x600
2000x600
2400x600
1 Focus A
1,05/m²
0,95/m²
0,85/m²
0,7/m²
2 Connect T24 Main runner, installed at 600 mm centres
1,7m/m²
1,7m/m²
1,7m/m²
1,7m/m²
3 Connect T24 Cross tee, L=600 mm
0,65m/m²
0,6m/m²
0,5m/m²
0,45m/m²
4 Connect Adjustable hanger, installed at 1500 mm centres (max. distance from wall 450 mm)
1,1/m²
1,1/m²
1,1/m²
1,1/m²
5 Connect Hanger clip
0,7/m²
0,7/m²
0,7/m²
0,7/m²
6 Connect Angle trim, fixed at 300 mm centres
as required
as required
as required
as required
7 Connect Shadow-line trim, fixed at 300 mm centres
as required
as required
as required
as required
Min. overall depth of system: 100 mm
-
-
-
-
Min. demounting depth: 100 mm
-
-
-
-
Acoustics
Acoustic:
-
Sound Absorption:
Test results according to EN ISO 354.
Classification according to EN ISO 11654, and the single value ratings for NRC and SAA according to ASTM C 423.
αp Practical sound absorption coefficient
Frequency Hz
— Ecophon Focus A 200 mm o.d.s.
--- Ecophon Focus A 50 mm o.d.s.
o.d.s = overall depth of system
product
Focus A
o.d.s mm
50
80
200
absorption class
B
A
A
Sound Insulation:
Dn,c,w=20 dB according to ISO 140-9 and evaluation according to EN ISO 717-1. CAC=21 dB according to ASTM E 1414 and evaluation according to ASTM E 413
Sound Privacy:
AC(1.5)=190 according to ASTM E 1111 and E 1110.
Technical info
Accessibility:
The tiles are easily demountable. Minimum demounting depth according to installation diagrams.
Cleanability:
Daily dusting and vacuum cleaning. Weekly wet wiping.
Visual appearance:
White Frost, nearest NCS colour sample S 0500-N, 85% light reflectance (of which more than 99% is diffuse reflection). Retro reflection coefficient 63 mcd*m-2lx-1. Gloss < 1.
Influence of climate:
The tiles withstand a permanent ambient RH up to 95% at 30°C without sagging, warping or delaminating (ISO 4611).
Indoor Climate:
Certified by the Indoor Climate Labelling, recommended by the Swedish Asthma and Allergy Association, and can be used in rooms classified as ISO class 6/M3.5.
Environmental influence:
Granted the Nordic Swan eco-label. Fully recyclable.
Fire safety:
The glass wool core of the tiles is tested and classified as non-combustible according to EN ISO 1182. The systems are classified as fire protective covering according to NT FIRE 003. See Technical properties, Fire safety.
Country
Class
Standard
Europe
EN 13501-1
A2-s1,d0
Mechanical properties:
For information regarding live load and requirements for load bearing capacity, see installation diagrams. Conditions: See Functional demands, Mechanical properties.
Installation:
Installed according to system range.
For Acousticians
"Acoustical evaluation of rooms requires several room acoustic descriptors. Reverberation time alone is not enough!" Erling Nilsson / Acoustics Specialist Ecophon
Copyright © 2002-2010 Ecophon Group. All rights reserved.
Trademarks
Cookies
Disclaimer
Tell a friend
Close
Your friends name:
*
Your friends email:
*
Your name:
*
Your e-mail:
*
Your message: