Search
Products
Solutions
References
Acoustics
Functional demands
Contact
About Ecophon
Career
SITEMAP
Focus
Focus additional systems
Master
Combison
Gedina
Advantage
Access
Sombra
Hygiene
Super G
Wall Panel
Ecophon Lighting
Focus™ A
Focus™ B
Focus™ C
Focus™ Dg
Focus™ Ds
Focus™ E
Focus™ Ebx
Focus™ F
Focus™ Wing
Focus Edge™ 500
Ecophon Focus™ Flexiform
Focus™ S-Line
Focus™ L-Line
Ecophon Focus™ Quadro E
Focus™ Frieze
Master™ A
Master™ B
Master™ C
Master™ Ds
Master™ E
Master™ F
Master™ Solo S
Master™ Baffle
Combison™ Uno A
Combison™ Uno Ds
Combison™ Duo A
Combison™ Duo E
Combison™ Barrier
Gedina™ A
Gedina™ E
Advantage™ A
Advantage™ E
Access™ A
Access™ C
Access™ E
Access™ Frieze
Sombra™ A
Sombra™ Ds
Hygiene Advance™ A C4
Hygiene Advance™ A C3
Hygiene Advance™ Baffle C3
Hygiene Advance™ Protection C3
Hygiene Advance™ Wall C3
Hygiene Foodtec™ A C3
Hygiene Foodtec™ Baffle C3
Hygiene Foodtec™ Wall C3
Hygiene Protec™ A C3
Hygiene Protec™ A C1
Hygiene Labotec™ Ds C1
Hygiene Performance™ A C4
Hygiene Performance™ A C3
Hygiene Performance™ A C1
Hygiene Meditec™ A C1
Hygiene Meditec™ E C1
Hygiene Lavanda™ T5 C3
Hygiene Foodtec™ Protection C3
Super G™
Super G™ Plus
Super G™ Dp XL
Wall Panel™ A
Wall Panel™ C
Ecophon Illuminated Level Change
Light Coffer
Dot™
Square 43™
Line™
WingLight™
Room types
Ideas and solutions
Colours and surfaces
Integrated lighting
Download our brochures here!
Concrete Core Activation
Connect Grids
Local references Germany
Local references Italy
Local references Sweden
Local references Netherlands
Local references
For Architects
For Acousticians
For Clients
For Users
Sound in offices
Noise in Offices
Ecophon Acoustic Bulletin
Accessibility
Limpieza
Visual appearance
Environment
Our certifications
Influence of climate
Fire Safety
Mechanical properties
CE-marking
Ecophon partners
Request information
Contact
ECO magazine- subscription
Subscribe to EcoMagazine
Disclaimer
Cookies
Trademarks
Testimonials
Available jobs
Workplace facts
Development opportunities
Environment Health Safety
HR Contact
Focus
Focus™ Dg
Tell a friend
Print
E-tools
Cad Support
Specifications
Maintenance manual
System and product description
Installation
Acoustics
Technical info
System range
Size, mm
XL
XL
XL
XL
600x600
1200x600
1200x1200
1600x600
1800x600
2000x600
2400x600
T24
•
•
•
•
•
•
•
Thickness
20
20
25
20
20
20
20
M202
M202
M203
M204
M204
M204
M204
System and product description
For applications where a unique demountable suspended ceiling is required. The edge design of the system conceals the support edges of the tile and creates a distinctive floating appearance. The suspension grid is approximately 14 mm above the visible surface of the tile, which gives the impression that each tile is individually suspended.The tiles are easily demountable even in areas where there is a very small overall depth of system.
The systems consist of Ecophon Focus Dg tiles and Ecophon Connect grid systems, with an approximate weight of 3-4 kg/m². The tiles are manufactured from high density glass wool. The visible surface has an Akutex FT coating and the back of the tile is covered with glass tissue. The edges are painted. For best performance and system quality, use Ecophon Connect grid and accessories. The grid is manufactured from galvanized steel. The tile is patented in the US, and patent pending in Europe.
M202
M203
M204
M202
Download installation guide
IG202
-Focus Dg
(947.10 kB)
Quantity specification (excl. wastage)
Installation diagram (M202) for Focus Dg 600x600, 1200x600 mm
Size, mm
600x600
1200x600
1 Ecophon Focus Dg
2,8/m²
1,4/m²
2 Connect T24 Main runner HD, installed at 1200 mm centres
0,9m/m²
0,9m/m²
3 Connect T24 Cross tee, L=1200 mm, installed at 600 mm centres
1,7m/m²
1,7m/m²
4 Connect T24 Cross tee, L=600 mm
0,9m/m²
-
5 Connect Wall bracket for T-profiles
1for every row of suspended Main runner HD
1for every row of suspended Main runner HD
6 Connect Support clip Dg20
1per perimeter tile, cut on the long side
1per perimeter tile, cut on the long side
7 Connect Adjustable hanger, installed at 1200 mm centres (max. distance from wall 600 mm)
0,7/m²
0,7/m²
8 Connect Hanger clip
0,7/m²
0,7/m²
9 For direct installation: Connect Direct bracket
0,7/m²
0,7/m²
10 Connect Angle trim, fixed at 300 mm centres
as required
as required
Min. overall depth of system, with Adjustable hanger: 115 mm, with Direct bracket: 65 mm
-
-
Min. demounting depth: 30 mm
-
-
M203
Download installation guide
IG203
-Focus Dg
(979.03 kB)
Quantity specification (excl. wastage)
Installation diagram (M203) for Focus Dg 1200x1200 mm
Size, mm
1200x1200
1 Focus Dg
0,7/m²
2 Connect T24 Main runner HD, installed at 1200 mm centres
0,9m/m²
3 Connect T24 Cross tee, L=1200 mm, installed at 600 mm centres
0,7m/m²
4 Connect Wall bracket for T-profiles
1for every row of suspended Main runner HD
5 Connect Edge clip
1,4on the long side of every cut perimeter tile
6 Connect Support clip Dg25
3/m²
7 Connect Adjustable hanger, installed at 1200 mm centres (max. distance from wall 600 mm)
0,7/m²
8 Connect Hanger clip
0,7/m²
9 For direct installation: Connect Direct bracket
0,7/m²
10 Connect Angle trim, fixed at 300 mm centres
as required
Min. overall depth of system, with Adjustable hanger: 115 mm, with Direct bracket: 65 mm
-
Min. demounting depth: 30 mm
-
M204
Quantity specification (excl. wastage)
Installation diagram (M204) for Focus Dg XL
Size, mm
1600x600
1800x600
2000x600
2400x600
1 Ecophon Focus Dg XL
1,05/m²
0,95/m²
0,85/m²
0,7/m²
2 Connect T24 Main runner HD, installed at 600 mm centres
1,7m/m²
1,7m/m²
1,7m/m²
1,7m/m²
3 Connect T24 Cross tee, L=600 mm
0,65m/m²
0,6m/m²
0,5m/m²
0,45m/m²
4 Connect Wall bracket for T-profiles
1for every row of suspended Main runner HD
1for every row of suspended Main runner HD
1for every row of suspended Main runner HD
1for every row of suspended Main runner HD
5 Connect Support clip Dg20
1/300-400mm on any cut edge
1/300-400mm on any cut edge
1/300-400mm on any cut edge
1/300-400mm on any cut edge
6 Connect Adjustable hanger, installed at 1500 mm centres (max. distance from wall 450 mm)
1,1/m²
1,1/m²
1,1/m²
1,1/m²
7 Connect Hanger clip
0,7/m²
0,7/m²
0,7/m²
0,7/m²
8 Connect Angle trim, fixed at 300 mm centres
as required
as required
as required
as required
Min. overall depth of system: 115 mm
-
-
-
-
Min. demounting depth: 30 mm
-
-
-
-
Acoustics
Acoustic:
product
Focus Dg 20 mm
Focus Dg 25 mm
o.d.s mm
65
75
200
65
200
absorption class
B
A
A
A
B
Sound Absorption:
Test results according to EN ISO 354.
Classification according to EN ISO 11654, and the single value ratings for NRC and SAA according to ASTM C 423.
Sound Insulation:
Not applicable.
Sound Privacy:
AC(1.5)=180 according to ASTM E 1111 and E 1110.
αp Practical sound absorption coefficient
Frequency Hz
— Ecophon Focus Dg 20 mm 200 mm o.d.s.
--- Ecophon Focus Dg 20 mm 65 mm o.d.s.
o.d.s = overall depth of system
Technical info
Accessibility:
The tiles in size 600x600 and 1200x600 are easliy demountable. The tiles in size 1200x1200 and XL sizes are demountable. Minimum demounting depth according to installation diagrams.
Cleanability:
Daily dusting and vacuum cleaning. Weekly wet wiping.
Visual appearance:
White Frost, nearest NCS colour sample S 0500-N, 85% light reflectance (of which more than 99% is diffuse reflection). Retro reflection coefficient 63 mcd*m-2lx-1. Gloss < 1.
Influence of climate:
The tiles withstand a permanent ambient RH up to 95% at 30°C without sagging, warping or delaminating (ISO 4611).
Indoor Climate:
Certified by the Indoor Climate Labelling, recommended by the Swedish Asthma and Allergy Association, and can be used in rooms classified as ISO class 6/M3.5.
Environmental influence:
Granted the Nordic Swan eco-label. Fully recyclable.
Fire safety:
The glass wool core of the tiles is tested and classified as non-combustible according to EN ISO 1182. The systems are classified as fire protective covering according to NT FIRE 003. See Technical properties, Fire safety.
Country
Class
Standard
Europe
EN 13501-1
A2-s1,d0
Mechanical properties:
For information regarding live load and requirements for load bearing capacity, see installation diagrams. Conditions: See Functional demands, Mechanical properties.
Installation:
Installed according to system range.
For Acousticians
"Acoustical evaluation of rooms requires several room acoustic descriptors. Reverberation time alone is not enough!" Erling Nilsson / Acoustics Specialist Ecophon
Copyright © 2002-2010 Ecophon Group. All rights reserved.
Trademarks
Cookies
Disclaimer
Tell a friend
Close
Your friends name:
*
Your friends email:
*
Your name:
*
Your e-mail:
*
Your message: