Search
Products
Solutions
References
Acoustics
Functional demands
Contact
About Ecophon
Career
SITEMAP
Focus
Focus additional systems
Master
Combison
Gedina
Advantage
Access
Sombra
Hygiene
Super G
Wall Panel
Ecophon Lighting
Focus™ A
Focus™ B
Focus™ C
Focus™ Dg
Focus™ Ds
Focus™ E
Focus™ Ebx
Focus™ F
Focus™ Wing
Focus Edge™ 500
Ecophon Focus™ Flexiform
Focus™ S-Line
Focus™ L-Line
Ecophon Focus™ Quadro E
Focus™ Frieze
Master™ A
Master™ B
Master™ C
Master™ Ds
Master™ E
Master™ F
Master™ Solo S
Master™ Baffle
Combison™ Uno A
Combison™ Uno Ds
Combison™ Duo A
Combison™ Duo E
Combison™ Barrier
Gedina™ A
Gedina™ E
Advantage™ A
Advantage™ E
Access™ A
Access™ C
Access™ E
Access™ Frieze
Sombra™ A
Sombra™ Ds
Hygiene Advance™ A C4
Hygiene Advance™ A C3
Hygiene Advance™ Baffle C3
Hygiene Advance™ Protection C3
Hygiene Advance™ Wall C3
Hygiene Foodtec™ A C3
Hygiene Foodtec™ Baffle C3
Hygiene Foodtec™ Wall C3
Hygiene Protec™ A C3
Hygiene Protec™ A C1
Hygiene Labotec™ Ds C1
Hygiene Performance™ A C4
Hygiene Performance™ A C3
Hygiene Performance™ A C1
Hygiene Meditec™ A C1
Hygiene Meditec™ E C1
Hygiene Lavanda™ T5 C3
Hygiene Foodtec™ Protection C3
Super G™
Super G™ Plus
Super G™ Dp XL
Wall Panel™ A
Wall Panel™ C
Ecophon Illuminated Level Change
Light Coffer
Dot™
Square 43™
Line™
WingLight™
Room types
Ideas and solutions
Colours and surfaces
Integrated lighting
Download our brochures here!
Concrete Core Activation
Connect Grids
Local references Germany
Local references Italy
Local references Sweden
Local references Netherlands
Local references
For Architects
For Acousticians
For Clients
For Users
Sound in offices
Noise in Offices
Ecophon Acoustic Bulletin
Accessibility
Limpieza
Visual appearance
Environment
Our certifications
Influence of climate
Fire Safety
Mechanical properties
CE-marking
Ecophon partners
Request information
Contact
ECO magazine- subscription
Subscribe to EcoMagazine
Disclaimer
Cookies
Trademarks
Testimonials
Available jobs
Workplace facts
Development opportunities
Environment Health Safety
HR Contact
Hygiene
Hygiene Advance™ A C4
Tell a friend
Print
E-tools
Cad Support
Specifications
Maintenance manual
System and product description
Installation
Acoustics
Technical info
System range
Size, mm
600x600
600x600
1200x600
1200x600
Thickness
20
40
20
40
M246
M246
M246
M246
System and product description
Ecophon Hygiene Advance A C4 is a unique wall to wall, sound absorbing ceiling system for use in demanding environments. Both the tiles and all the suspension components, made of acid-proof stainless steel, can endure daily wet cleaning with strong detergents and disinfectants. Examples of applications: areas with constantly high humidity and risk for corrosion; dish rooms and fish industry.
The system consists of Ecophon Hygiene Advance A tiles, which have a core of high density glass wool fully encapsulated in a smooth high-performance film that is impervious to particles and water. The film is also dirt-repellent and resistant to most chemicals. The supporting structure is an exposed Connect T24 C4 grid made of acid-proof high-performance austenitic stainless steel to avoid stress corrosion that can occur on ordinary stainless steel. The weight of the system is 3-4 kg/m2. The tiles should be secured to the grid with Connect Hygiene clips in order to withstand pressure during cleaning and to minimise dirt traps. For access to the plenum a special Connect Democlip is used together with a Ecophon Hygiene Advance A tile in 20 mm thickness.
The Ecophon Hygiene Advance A C4 is a technical ceiling system which might have aesthetic variations that will not affect the functionality of the system.
M246
M246
Download installation guide
IG246
-Hygiene Adv C4 A
(2.70 MB)
Quantity specification (excl. wastage)
Installation diagram (M246) for Ecophon Hygiene Advance A C4
Size, mm
600x600
1200x600
1 Ecophon Hygiene Advance A
2,8/m²
1,4/m²
2 Connect T24 Main runner C4, c1200
0,9m/m²
0,9m/m²
3 Connect T24 Cross tee C4, L=1200, c600
1,7m/m²
1,7m/m²
4 Connect T24 Cross tee C4, L=600
0,9m/m²
-
5 Connect Adjustable hanger C4, c1200, (max 600 mm distance from wall)
0,7/m²
0,7/m²
6 Connect Hygiene clip 20 C4
11/m²
7/m²
7 Connect Hygiene clip 40 C4
11/m²
7/m²
8 Connect Channel trim C4, fixed at c300 mm
as required
as required
9 Connect Demo clips 20 C4, (where access is needed)
as required
as required
10 Connect Fixing plate C4
0,7/m²
0,7/m²
11 Connect Anchor screw C4
0,7/m²
0,7/m²
12 Connect Installation screw C4
3,4/lm Channel trim C4
3,4/lm Channel trim C4
13 Ecophon Hygiene Advance technical tile (thickness 20 mm)
as required
as required
14 Joint sealant (not supplied by Ecophon)
as required
as required
15 Ecophon Hygiene Advance A 20 mm (where access is needed)
as required
as required
16 Connect Hygiene Advance Tape
as required
as required
Min. overall depth of system: 150 mm
-
-
Min. demounting depth: 150 mm
-
-
Acoustics
Acoustic:
Sound Absorption:
Test results according to EN ISO 354.
Classification according to EN ISO 11654.
Sound Insulation:
Not applicable.
Sound Privacy:
Not applicable
product
Hygiene Advance A C4, 20 mm thick
Hygiene Advance A C4, 40 mm thick
o.d.s mm
200
200
absorption class
B
A
Technical info
Accessibility:
The tiles are demountable. Minimum demounting depth according to installation diagram. The tiles are secured using Hygiene Clip 20 to allow for effective in-situ cleaning. The clips are easily removable from above the ceiling. A tightly sealed, easy-to-open Hygiene Inspection hatch is available to simplify access to the ceiling void.
Cleanability:
Daily dusting, vacuum cleaning, manual wet cleaning and high-pressure washing. Water temperature max. 70°C. Can withstand the use of common disinfecting chemicals.
Visual appearance:
White 141, nearest NCS colour sample S 1000-N, 73% light reflectance. Please note: There is a small difference in gloss between the Hygiene Advance tile and the Hygiene Advance perimeter tile.
Influence of climate:
The tiles withstand a permanent ambient RH up to 95% at 30°C without sagging, warping or delaminating (ISO 4611).
Indoor Climate:
Can be used in rooms classified as ISO class 5/M2.5.
Fire safety:
The glass wool core of the tiles is tested and classified as non-combustible according to EN ISO 1182. See Technical properties, Fire safety.
Country
Class
Standard
Europe
EN 13501-1
A2-s1,d0
Mechanical properties:
For information regarding live load and requirements for load bearing capacity, see installation diagrams. Conditions: See Functional demands, Mechanical properties.
Installation:
Installed according to system range. Cut tiles must be sealed with Connect Hygiene Advance Tape.
For Acousticians
"Acoustical evaluation of rooms requires several room acoustic descriptors. Reverberation time alone is not enough!" Erling Nilsson / Acoustics Specialist Ecophon