Hygiene
Hygiene Foodtec™ A C3
System range
Size, mm
600x600 600x600 1200x600 1200x600
Thickness 20 40 20 40
M249 M249 M249 M249
System and product description
Ecophon Hygiene Foodtec A C3 is a wall to wall, sound-absorbing ceiling system intended for environments where there is risk for contaminations, and where frequent cleaning is required. This system is recommended where humidity levels are occasionally high. Examples of applications: the food and beverage industries, restaurants and catering kitchens.

The system consists of Ecophon Hygiene Foodtec A tiles, which have a core of high density glass wool and a painted stain protected Akutex HS surface. The back and the edges are painted. The tile is designed to be demounted and cleaned on a regular basis. The supporting structure is a corrosion protected exposed Connect T24 C3 grid of lacquered galvanised steel. The weight of the system is 3-4 kg/m2. The tiles should be secured to the grid with Connect Hygiene clips in order to withstand pressure during cleaning and to minimise.
Acoustics
Acoustic:
Sound Absorption: Test results according to EN ISO 354.
Classification according to EN ISO 11654.
Sound Insulation: Not applicable.
Sound Privacy: Not applicable
product Hygiene Foodtec A C3, 20 mm thick Hygiene Foodtec A C3, 40 mm thick
o.d.s mm 200 200
absorption class A A
Technical info
Accessibility: The tiles are demountable. Minimum demounting depth according to installation diagram. The tiles are secured using Hygiene Clip 20 to allow for effective in-situ cleaning. The clips are easily removable from above the ceiling. A tightly sealed, easy-to-open Hygiene Inspection hatch is available to simplify access to the ceiling void.
Cleanability: Daily dusting and vacuum cleaning. Weekly wet cleaning on all surfaces and high-pressure washing twice a year. Can withstand the use of common disinfecting chemicals.
Light efficiency: Colours: See Ecophon colour range.
Influence of climate: The tiles withstand a permanent ambient RH up to 95% at 30°C without sagging, warping or delaminating (ISO 4611).
Indoor Climate: Certified by the Indoor Climate Labelling, recommended by the Swedish Asthma and Allergy Association, and can be used in rooms classified as ISO class 5/M2.5.
Environmental influence: Granted the Nordic Swan eco-label. Fully recyclable.
Fire safety: The glass wool core of the tiles is tested and classified as non-combustible according to EN ISO 1182. See Technical properties, Fire safety.
Country Class Standard
Europe EN 13501-1 A2-s1,d0
Mechanical properties: For information regarding live load and requirements for load bearing capacity, see installation diagrams. Conditions: See Functional demands, Mechanical properties.
Installation: Installed according to system range. Cut tiles must be sealed with Connect Hygiene Advance Tape.
"Acoustical evaluation of rooms requires several room acoustic descriptors. Reverberation time alone is not enough!" Erling Nilsson / Acoustics Specialist Ecophon