Hygiene
Hygiene Foodtec™ Baffle C3
System range
Size, mm
1200x600
T24
Thickness 50
M263 M264
System and product description
Ecophon Hygiene Foodtec Baffle C3 is an open system with vertical baffles intended for use in environment where there is risk for contaminations, and where frequent cleaning is required. This system is recommended where humidity levels are occasionally high. It is used mainly in premises where it is not possible to install a wall to wall ceiling because of sprinkler systems, installations or skylights, etc. Examples of applications: the food and beverage industries, restaurants and catering.

The system consists of Ecophon Hygiene Foodtec Baffles, which have a core of high density glass wool and a painted stain protected Akutex HS surface both sides. The edges are painted. The supporting structure is a corrosion protected exposed Connect T24 C3 grid of lacquered galvanised steel. The weight of the system is 3-4 kg/m2.
Acoustics
Acoustic:
Sound Absorption: Test results according to EN ISO 354.
Classification according to EN ISO 11654.
Sound Insulation: Not applicable.
product Hygiene Foodtec Baffle C3 in rows, c 600 mm, with ~1,4 baffles per m² of ceiling area Hygiene Foodtec Baffle C3 in chequered pattern, with ~1,3 baffles per m² of ceiling area
o.d.s mm - -
absorption class C C
Technical info
Accessibility: The tiles are demountable.
Cleanability: Daily dusting and vacuum cleaning. Weekly wet cleaning on all surfaces and high-pressure washing twice a year. Can withstand the use of common disinfecting chemicals.
Light efficiency: Colours: See Ecophon colour range.
Influence of climate: The tiles withstand a permanent ambient RH up to 95% at 30°C without sagging, warping or delaminating (ISO 4611).
Indoor Climate: Certified by the Indoor Climate Labelling, recommended by the Swedish Asthma and Allergy Association, and can be used in rooms classified as ISO class 5/M2.5.
Environmental influence: Granted the Nordic Swan eco-label. Fully recyclable.
Fire safety: The glass wool core of the tiles is tested and classified as non-combustible according to EN ISO 1182. See Technical properties, Fire safety.
Country Class Standard
Europe EN 13501-1 A2-s1,d0
Mechanical properties: For information regarding live load and requirements for load bearing capacity, see installation diagrams. Conditions: See Functional demands, Mechanical properties.
Installation: Installed according to system range. Cut tiles must be sealed with Connect Hygiene Advance Tape.
"Acoustical evaluation of rooms requires several room acoustic descriptors. Reverberation time alone is not enough!" Erling Nilsson / Acoustics Specialist Ecophon