System and product description
Ecophon Hygiene Labotec Ds C1 is a wall to wall, sound-absorbing ceiling system intended for environments where there are demands on low particle emission and where occasional wet wiping and/or disinfection is required. The Ds system has only vertical joints which minimise dirt traps. Examples of applications: laboratories in, for example, the pharmaceutical, electronics industries and in healthcare premises.
The system consists of Ecophon Hygiene Labotec Ds tiles, which have a core of high density glass wool and a painted particle-repellent Akutex™ HP surface. The back and the edges are painted. The supporting structure is a consealed Connect grid of galvanised steel. The weight of the system is 3-4 kg/m². The tiles should be secured to the grid with Connect Hold down clip Ds in order to withstand pressure during cleaning and still make them demountable from below. The grid system is patented.
M251
M251
VIEW 3D
Download installation guide
IG251
-Hygiene Labotec Ds
(2.30 MB)
Drawing Aid
Transitions
Installations
Fixings
Search
See Quantity specification
Arrangement of clips
Demounting of tile from below
Mounting of Hold Down clip Ds
Quantity specification (excl. wastage)
Installation diagram (M251) for Ecophon Hygiene Labotec Ds C1
Size, mm
600x600
1200x600
1 Hygiene Labotec Ds
2,8/m²
1,4/m²
2 Connect T24 Main runner HD, installed at 600 mm centres
1,7m/m²
1,7m/m²
3 Connect Wall bracket for T-profiles
1for every row of suspended Main runner HD
1for every row of suspended Main runner HD
4 Connect Space bar, installed at 1500 mm centres (max. distance from wall 300 mm)
0,7m/m²
0,7m/m²
5 Connect Wall bracket, L=700 mm, for Space bar
1 for every row of Space bar
1 for every row of Space bar
6 Connect T24 Cross tee, L=600 mm
2per row of Main runner
2per row of Main runner
7 Connect Space bar winch, installed one per joint Main runner/Space bar
1,4/m²
1,4/m²
8 Connect Adjustable hanger, installed at 1200 mm centres (max. distance from wall 600 mm)
0,7/m²
0,7/m²
9 Connect Hanger clip
0,7/m²
0,7/m²
10 Alt. Connect Frieze trim, fixed c300 mm
as required
as required
11 Connect Frieze bracket, installed at 500 mm centre. Minimum free depth above tile 150 mm.
2/cut tile with one bearing edge
3/cut tile with one bearing edge
12 Connect Hold down clip Ds
2/tile, 50-100 mm from corners
3/tile, 50-100 mm from corners
13 Joint sealant (not supplied by Ecophon)
as required
as required
Δ Min. overall depth of system: 170 mm
-
-
δ Min. demounting depth: 30 mm
-
-
Acoustics
Acoustic:
α
p
Practical sound absorption coefficient
Frequency, Hz
—
Ecophon Hygiene Labotec Ds C1, 200 mm o.d.s.
o.d.s= overall depth of system
Sound Absorption:
Test results according to EN ISO 354.
Classification according to EN ISO 11654.
Sound Insulation:
Not applicable.
Sound Privacy:
Not applicable
Product
Hygiene Labotec Ds C1
o.d.s mm
200
absorption class
A
αw
Technical properties
Accessibility:
The tiles are demountable.
Cleanability:
Daily dusting and vacuum cleaning. Weekly wet wiping. Steam cleaning four times/year. Can withstand the use of common disinfecting chemicals.
Visual appearance:
White 500, nearest NCS colour sample S 0500-N, 84% light reflectance.
Influence of climate:
The tiles withstand a permanent ambient RH up to 95% at 30°C without sagging, warping or delaminating (ISO 4611). A higher temperature/moisture is permissible during washing as stated above. The grid and accessories meet the demands of corrosion class C1 according to EN ISO 12944-2. For the microbiological resistance see Functional demands, Influence of climate.
Indoor Climate:
Certified by the Indoor Climate Labelling, emission class M1 for building materials, recommended by the Swedish Asthma and Allergy Association, and can be used in rooms classified as ISO class 5 according to ISO 14644-1.
Environmental influence:
Granted the Nordic Swan eco-label. Fully recyclable.
Fire safety:
The glass wool core of the tiles is tested and classified as non-combustible according to prEN ISO 1182. The systems are classified as fire protective covering according to NT FIRE 003. See Technical properties, Fire safety.
Country
Standard
Class
Europe
EN 13501-1
A2-s1,d0
Mechanical properties:
For information regarding live load and requirements for load bearing capacity, see installation diagrams. Conditions: See Functional demands, Mechanical properties.
Max live load (N)
Min load bearing capacity (N)
M251
, 600x600
50
160
M251
, 1200x600
50
160
Installation:
Installed according to system range. Cut panels must be sealed with Connect Edge sealant.
Contact Us
We help you with technical solutions and answers to your questions about our products.
Read more
Hygiene Premises overview
Hygiene system overview & Quickguide - Room types
Download
Hygiene system brochure.pdf
3D CAD
A new feature turns watching installation diagrams into a 3D experience! Add another dimension to watching our installation diagrams. With our latest innovation we let you twist and turn and view close-ups directly on your computer.
Read more
Copyright © 2002-2012 Ecophon Group. All rights reserved.
Trademarks
Cookies
Disclaimer
Tell a friend
Close
Your friends name:
*
Your friends email:
*
Your name:
*
Your e-mail:
*
Your message:
Transitions
Installation
Fixing
Search
Subcategory
Detail list
Previous image
Next image
Type
Name
Description
Product
Sketch
Result
Previous image
Next image
Close