Search
Products
Solutions
References
Acoustics
Functional demands
Contact
About Ecophon
Career
SITEMAP
Focus
Focus additional systems
Master
Combison
Gedina
Advantage
Access
Sombra
Hygiene
Super G
Wall Panel
Ecophon Lighting
Focus™ A
Focus™ B
Focus™ C
Focus™ Dg
Focus™ Ds
Focus™ E
Focus™ Ebx
Focus™ F
Focus™ Wing
Focus Edge™ 500
Ecophon Focus™ Flexiform
Focus™ S-Line
Focus™ L-Line
Ecophon Focus™ Quadro E
Focus™ Frieze
Master™ A
Master™ B
Master™ C
Master™ Ds
Master™ E
Master™ F
Master™ Solo S
Master™ Baffle
Combison™ Uno A
Combison™ Uno Ds
Combison™ Duo A
Combison™ Duo E
Combison™ Barrier
Gedina™ A
Gedina™ E
Advantage™ A
Advantage™ E
Access™ A
Access™ C
Access™ E
Access™ Frieze
Sombra™ A
Sombra™ Ds
Hygiene Advance™ A C4
Hygiene Advance™ A C3
Hygiene Advance™ Baffle C3
Hygiene Advance™ Protection C3
Hygiene Advance™ Wall C3
Hygiene Foodtec™ A C3
Hygiene Foodtec™ Baffle C3
Hygiene Foodtec™ Wall C3
Hygiene Protec™ A C3
Hygiene Protec™ A C1
Hygiene Labotec™ Ds C1
Hygiene Performance™ A C4
Hygiene Performance™ A C3
Hygiene Performance™ A C1
Hygiene Meditec™ A C1
Hygiene Meditec™ E C1
Hygiene Lavanda™ T5 C3
Hygiene Foodtec™ Protection C3
Super G™
Super G™ Plus
Super G™ Dp XL
Wall Panel™ A
Wall Panel™ C
Ecophon Illuminated Level Change
Light Coffer
Dot™
Square 43™
Line™
WingLight™
Room types
Ideas and solutions
Colours and surfaces
Integrated lighting
Download our brochures here!
Concrete Core Activation
Connect Grids
Local references Germany
Local references Italy
Local references Sweden
Local references Netherlands
Local references
For Architects
For Acousticians
For Clients
For Users
Sound in offices
Noise in Offices
Ecophon Acoustic Bulletin
Accessibility
Limpieza
Visual appearance
Environment
Our certifications
Influence of climate
Fire Safety
Mechanical properties
CE-marking
Ecophon partners
Request information
Contact
ECO magazine- subscription
Subscribe to EcoMagazine
Disclaimer
Cookies
Trademarks
Testimonials
Available jobs
Workplace facts
Development opportunities
Environment Health Safety
HR Contact
Master
Master™ Baffle
Tell a friend
Print
E-tools
Cad Support
Specifications
Maintenance manual
System and product description
Installation
Acoustics
Technical info
System range
Size, mm
1200x200
1200x300
Special Fixing
Thickness
40
40
M232
M232
System and product description
For applications where a wall-to-wall ceiling is not possible or desired. Such applications are, for example, concrete core activation or installations that do not allow a full coverage of the ceiling. Ecophon Master Baffle is an easily demountable system with a distinct gap between the baffles created by the Connect guiding pin.
The systems consist of Ecophon Master Baffles and Ecophon Connect details with an approximate weight of 2-3 kg/m. The baffles are manufactured from high density glass wool. The visible surface has an Akutex FT coating apart from the edges that are painted. The grid is manufactured from galvanized steel.
M232
M232
Download installation guide
IG232
-Master Baffle
(459.47 kB)
Quantity specification (excl. wastage)
Installation diagram (M232) for Master Baffle
Size, mm
1200x200
1200x300
1 Ecopon Master Baffle
2,8/m²
2,8/m²
2 Connect Baffle Profile, installed at 300 mm centres
3,3m/m²
3,3m/m²
3 Connect Anchor Screw, fixed at 1200 mm centres
4,2/m²
4,2/m²
4 Connect Profile connector, installed at 2400 mm centres
1,4/m²
1,4/m²
5 Connect Guiding pin, installed at 1200 mm centres
2,8/m²
2,8/m²
Acoustics
Acoustic:
product
Master Baffle
o.d.s mm
200
300
absorption class
D
D
Sound Absorption:
Test results according to EN ISO 354.
Classification according to EN ISO 11654, and the single value ratings for NRC and SAA according to ASTM C 423.
Sound Insulation:
Not applicable.
Sound Privacy:
Not applicable
αp Practical sound absorption coefficient
Frequency Hz
Frequency, Hz
— Ecophon Master Baffle, height 300 mm, spacing 300 mm, direct mounted
···· Ecophon Master Baffle, height 300 mm, spacing 500 mm, direct mounted
— Ecophon Master Baffle, height 200 mm, spacing 300 mm, direct mounted
Technical info
Installation:
Installed according to system range.
For Acousticians
"Acoustical evaluation of rooms requires several room acoustic descriptors. Reverberation time alone is not enough!" Erling Nilsson / Acoustics Specialist Ecophon
Copyright © 2002-2010 Ecophon Group. All rights reserved.